header-logo

HUADONG CABLE GROUP

Professional Cables and Wires Manufacturer in China

Control Cable (CVV, CVV-S, CVV-SWA)

CVV control cable

CVV 0.6/1KV Control Cable

Conductor: Concentric Stranded copper wire
Cores: 2-30 core
Insulation: PVC Black color
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Sheath: PVC Black color
Application: For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.

Get a free quote by e-mail:  sales@huadongcablegroup.com

 

4 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
40.57/0.300.81.811360.0162130500/D
0.757/0.370.81.811.524.50.0142150500/D
17/0.400.81.811.518.10.0135160500/D
1.57/0.500.81.812.512.10.0115195500/D
2.57/0.670.81.8147.410.0093265500/D
47/0.8511.816.54.610.0092390500/D
67/1.0411.8173.080.0078510500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

5 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
50.57/0.300.81.811.5360.0162150500/D
0.757/0.370.81.812.524.50.0142175500/D
17/0.400.81.812.518.10.0135190500/D
1.57/0.500.81.813.512.10.0115230500/D
2.57/0.670.81.8157.410.0093320500/D
47/0.8511.8184.610.0092470500/D
67/1.0411.819.53.080.0078620500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

6 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
60.57/0.300.81.812.5360.0162165500/D
0.757/0.370.81.81324.50.0142190500/D
17/0.400.81.813.518.10.0135205500/D
1.57/0.500.81.814.512.10.0115255500/D
2.57/0.670.81.8167.410.0093355500/D
47/0.8511.819.54.610.0092525500/D
67/1.0411.8213.080.0078690500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

7 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
70.57/0.300.81.812.5360.0162170500/D
0.757/0.370.81.81324.50.0142200500/D
17/0.400.81.813.518.10.0135215500/D
1.57/0.500.81.814.512.10.0115270500/D
2.57/0.670.81.8167.410.0093380500/D
47/0.8511.819.54.610.0092570500/D
67/1.0411.8213.080.0078795500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

8 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
80.57/0.300.81.813.5360.0162195500/D
0.757/0.370.81.81424.50.0142230500/D
17/0.400.81.814.518.10.0135250500/D
1.57/0.500.81.815.512.10.0115310500/D
2.57/0.670.81.817.57.410.0093440500/D
47/0.8511.8214.610.0092660500/D
67/1.0411.8233.080.0078875500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

The other size for 0.6/1KV CVV Control Cable we can produce according to your requirement.

CVV-S Control cable

CVV-S 0.6/1KV Control Cable 60502 Standard

Conductor: Concentric Stranded copper wire
Core: 2-15 cores
Insulation: PVC Black color
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Inner sheath: PVC Black color
Shield: Annealed copper tape
Binding tape: Suitable tape
Outer Sheath: PVC Black color
Application: For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.

Get a free quote by e-mail:  sales@huadongcablegroup.com

 

4 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
40.57/0.300.811.813.5360.0162220500/D
0.757/0.370.811.81424.50.0142245500/D
17/0.400.811.814.518.10.0135260500/D
1.57/0.500.811.815.512.10.0115300500/D
2.57/0.670.811.816.57.410.0093385500/D
47/0.85111.8194.610.0092530500/D
67/1.04111.820.53.080.0078660500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

5 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
50.57/0.300.811.814.5360.0162250500/D
0.757/0.370.811.81524.50.0142280500/D
17/0.400.811.815.518.10.0135295500/D
1.57/0.500.811.816.512.10.0115345500/D
2.57/0.670.811.8187.410.0093445500/D
47/0.85111.820.54.610.0092620500/D
67/1.04111.822.53.080.0078780500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

6 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
60.57/0.300.811.815.5360.0162270500/D
0.757/0.370.811.81624.50.0142305500/D
17/0.400.811.816.518.10.0135320500/D
1.57/0.500.811.817.512.10.0115375500/D
2.57/0.670.811.8197.410.0093290500/D
47/0.85111.8224.610.0092685500/D
67/1.04111.8243.080.0078865500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

7 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
70.57/0.300.811.815.5360.0162275500/D
0.757/0.370.811.81624.50.0142315500/D
17/0.400.811.816.518.10.0135330500/D
1.57/0.500.811.817.512.10.0115395500/D
2.57/0.670.811.8197.410.0093520500/D
47/0.85111.8224.610.0092730500/D
67/1.04111.8243.080.0078930500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

8 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
80.57/0.300.811.816360.0162310500/D
0.757/0.370.811.81724.50.0142350500/D
17/0.400.811.81718.10.0135370500/D
1.57/0.500.811.818.512.10.0115445500/D
2.57/0.670.811.8207.410.0093590500/D
47/0.85111.823.54.610.0092835500/D
67/1.04111.825.53.080.00781070500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

[

The other size for 0.6/1KV CVV-S Control Cable we can produce according to your requirement.

CVV-SWA control cable

CVV-SWA 0.6/1KV Control Cable

Conductor: Concentric Stranded annealed copper wire
Insulation: PVC Black color
Core: 2-30 Core
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Inner sheath: PVC Black color
Armour: Galvanized steel wire
Binding tape: Suitable tape
Outer Sheath: PVC Black color
Application: For use in duct, tray and for direct burying in ground. The cable subjects to immerse in water all the line.

Get a free quote by e-mail:  sales@huadongcablegroup.com

 

4 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
40.57/0.300.81.20.81.816.5360.0162380500/D
0.757/0.370.81.20.81.81724.50.0142410500/D
17/0.400.81.20.81.81718.10.0135425500/D
1.57/0.500.81.20.81.81812.10.0115480500/D
2.57/0.670.81.21.251.820.57.410.0093715500/D
47/0.8511.21.251.8234.610.0092915500/D
67/1.0411.21.251.824.53.080.00781075500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

5 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
50.57/0.300.81.20.81.817360.0162420500/D
0.757/0.370.81.20.81.81824.50.0142455500/D
17/0.400.81.21.251.81918.10.0135595500/D
1.57/0.500.81.21.251.82012.10.0115665500/D
2.57/0.670.81.21.251.821.57.410.0093805500/D
47/0.8511.21.251.824.54.610.00921040500/D
67/1.0411.21.61.8273.080.00781385500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

6 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
60.57/0.300.81.20.81.818360.0162450500/D
0.757/0.370.81.21.251.819.524.50.0142610500/D
17/0.400.81.21.251.82018.10.0135635500/D
1.57/0.500.81.21.251.82112.10.0115715500/D
2.57/0.670.81.21.251.822.57.410.0093870500/D
47/0.8511.21.61.826.54.610.00921270500/D
67/1.0411.21.61.828.53.080.00781515500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

7 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
70.57/0.300.81.20.81.818360.0162455500/D
0.757/0.370.81.21.251.819.524.50.0142620500/D
17/0.400.81.21.251.82018.10.0135650500/D
1.57/0.500.81.21.251.82112.10.0115730500/D
2.57/0.670.81.21.251.822.57.410.0093895500/D
47/0.8511.21.61.826.54.610.00921315500/D
67/1.0411.21.61.828.53.080.00781580500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

8 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
80.57/0.300.81.21.251.820360.0162625500/D
0.757/0.370.81.21.251.820.524.50.0142680500/D
17/0.400.81.21.251.82118.10.0135710500/D
1.57/0.500.81.21.251.82212.10.0115810500/D
2.57/0.670.81.21.251.8247.410.0093995500/D
47/0.8511.21.61.8284.610.00921470500/D
67/1.0411.21.61.8303.080.00781770500/D

Get the quote by e-mail:  sales@huadongcablegroup.com

The other size for 0.6/1KV CVV-SWA Control Cable we can produce according to your requirement.

 

Why Choose Us

Please feel free to leave your requirement, We will reply you in 12 hours.

    E-mail: sales@huadongcablegroup.com

    Your Name

    * Your Email

    Your Phone Number

    Your Country

    * Your Requirement

    whatapp-icon
    email-icon Send Email
    Inquiry

      sales@huadongcablegroup.com

      Name

      Email *

      Phone

      Requirement *

      x